3.2.1 Heater tank, tray pack, size and configuration. The tray pack heater tank (reference
figure 1) shall have a capacity of not less than 20 gallons of water and 20 tray packs (reference
figure 2) and shall have a visual mark on the inside at the 20-gallon level. The tank assembly
shall be approximately 37 inches high and shall accommodate a Modern Burner Unit(MBU) (see
6.6.1). The tank assembly shall have two handles on the front and two on the rear that fold down
along the tank's vertical surfaces when not in use. When the handles are utilized, they shall not
rotate upward more than approximately 90 degrees. The heater tank shall be provided with a
two- section cover, split in the center, hinged on each side and capable of being secured in the
closed position with latches. Each tank shall contain a drain, a drain ball valve and a drain pipe
with a hose adapter.
3.2.2 Heater tank, tray pack, heating. The heater tank assembly shall permit water to be
rapidly heated, and shall withstand direct heat from the burner unit (see 6.6.1).
3.2.3 Heater tank, tray pack, drainage. The tank drain shall permit rapid drainage.
3.2.4 Heater tank, tray pack, leakage. The tank shall not leak.
3.2.5 Heater tank, tray pack, warning plates. Warning plates that specify, "Warning, May
Be Hot" shall be mounted to the front and back of the tank. Marking shall be durable.
3.2.6 Heater tank, tray pack, operating instructions plate. An operating instruction plate
shall be provided on the front of the tank assembly and shall specify the following:
"1.
Place burner in rack
2.
Fill with 20 gallons of water for full load of 20 tray packs
3.
Light burner per TM 10-7310-281-13 &P
4.
Bring water to a boil leaving burner on high setting
5.
Place tray packs in tank being sure they are completely covered with water
6.
Heat tray packs for 45 minutes
8.
Remove tray packs using tray pack lifter
9.
Shut burner off by pressing stop"
Marking shall be durable.
3.3 Griddle operating requirements. The KCLFF component identified in table II
(reference figure 3) shall satisfy the following requirements.